EDS-P506E Series

Introduction
The EDS-P506E Series includes Gigabit managed PoE+ Ethernet switches that come standard with 4 10/100BaseT(X), 802.3af (PoE), and 802.3at (PoE+)-compliant Ethernet ports, and 2 combo Gigabit Ethernet ports. The EDS-P506E Series provides up to 30 watts of power per PoE+ port in standard mode and allows a high-power output of up to 4-pair 60 W for industrial heavy-duty PoE devices, such as weather-proof IP surveillance cameras with wipers/heaters, high-performance wireless access points, and rugged IP phones.

The EDS-P506E Series is highly versatile, and the SFP fiber ports can transmit data up to 120 km from the device to the control center with high EMI immunity. The Ethernet switches support a variety of management functions, including STP/RSTP, Turbo Ring, Turbo Chain, PoE power management, PoE device auto-checking, PoE power scheduling, PoE diagnostic, IGMP, VLAN, QoS, RMON, bandwidth management, and port mirroring. The EDS-P506E Series is designed especially for harsh outdoor applications with 4 kV surge protection to ensure uninterrupted reliability of PoE systems.

 

Additional Features and Benefits

  • Supports different PoE output settings (High-power 36 W and 60 W, Force and Legacy modes) to maximize powered device compatibility
  • Supports Smart PoE functions (PoE diagnosis, PD failure check, PoE scheduling, and PoE Event Warning) to enhance PoE operational efficiency
  • Command line interface (CLI) for quickly configuring major managed functions
  • Supports EtherNet/IP, PROFINET, and Modbus TCP protocols for device management and monitoring
  • Supports V-ON™ to ensure millisecond-level Layer2/Layer3 network recovery
  • Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), RSTP/STP, and MSTP for network redundancy
  • Automatic warning by exception through email and relay output
  • Port mirroring for online debugging
  • IGMP snooping and GMRP for filtering multicast traffic
  • Port-based VLAN, IEEE 802.1Q VLAN, and GVRP to ease network planning
  • QoS (IEEE 802.1p/1Q and TOS/DiffServ) to increase determinism
  • Port Trunking for optimum bandwidth utilization
  • RADIUS, TACACS+, MAB Authentication, SNMPv3, IEEE 802.1x, MAC ACL, HTTPS, SSH, and sticky MAC address to enhance network security
  • SNMPv1/v2c/v3 for different levels of network management
  • Fiber Check™ provides a comprehensive fiber Digital Diagnostic Monitoring (DDM) function and event warning on SFP fiber ports
  • Bandwidth management to prevent unpredictable network status
  • ABC-02-USB (Automatic Backup Configurator) for system configuration backup/restore and firmware upgrade

EDS-P506E Series

Features and Benefits

  • Built-in 4 PoE+ ports support up to 60 W output per port
  • Wide-range 12/24/48 VDC power inputs for flexible deployment
  • Smart PoE functions for remote power device diagnosis and failure recovery
  • 2 Gigabit combo ports for high-bandwidth communication
  • Supports MXstudio for easy, visualized industrial network management

Certifications

Download Datasheet

View List

Description

Introduction
The EDS-P506E Series includes Gigabit managed PoE+ Ethernet switches that come standard with 4 10/100BaseT(X), 802.3af (PoE), and 802.3at (PoE+)-compliant Ethernet ports, and 2 combo Gigabit Ethernet ports. The EDS-P506E Series provides up to 30 watts of power per PoE+ port in standard mode and allows a high-power output of up to 4-pair 60 W for industrial heavy-duty PoE devices, such as weather-proof IP surveillance cameras with wipers/heaters, high-performance wireless access points, and rugged IP phones.

The EDS-P506E Series is highly versatile, and the SFP fiber ports can transmit data up to 120 km from the device to the control center with high EMI immunity. The Ethernet switches support a variety of management functions, including STP/RSTP, Turbo Ring, Turbo Chain, PoE power management, PoE device auto-checking, PoE power scheduling, PoE diagnostic, IGMP, VLAN, QoS, RMON, bandwidth management, and port mirroring. The EDS-P506E Series is designed especially for harsh outdoor applications with 4 kV surge protection to ensure uninterrupted reliability of PoE systems.

 

Additional Features and Benefits

  • Supports different PoE output settings (High-power 36 W and 60 W, Force and Legacy modes) to maximize powered device compatibility
  • Supports Smart PoE functions (PoE diagnosis, PD failure check, PoE scheduling, and PoE Event Warning) to enhance PoE operational efficiency
  • Command line interface (CLI) for quickly configuring major managed functions
  • Supports EtherNet/IP, PROFINET, and Modbus TCP protocols for device management and monitoring
  • Supports V-ON™ to ensure millisecond-level Layer2/Layer3 network recovery
  • Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), RSTP/STP, and MSTP for network redundancy
  • Automatic warning by exception through email and relay output
  • Port mirroring for online debugging
  • IGMP snooping and GMRP for filtering multicast traffic
  • Port-based VLAN, IEEE 802.1Q VLAN, and GVRP to ease network planning
  • QoS (IEEE 802.1p/1Q and TOS/DiffServ) to increase determinism
  • Port Trunking for optimum bandwidth utilization
  • RADIUS, TACACS+, MAB Authentication, SNMPv3, IEEE 802.1x, MAC ACL, HTTPS, SSH, and sticky MAC address to enhance network security
  • SNMPv1/v2c/v3 for different levels of network management
  • Fiber Check™ provides a comprehensive fiber Digital Diagnostic Monitoring (DDM) function and event warning on SFP fiber ports
  • Bandwidth management to prevent unpredictable network status
  • ABC-02-USB (Automatic Backup Configurator) for system configuration backup/restore and firmware upgrade

Specification

Filter802.1Q VLAN, GMRP, GVRP, IGMP v1/v2/v3, Port-based VLAN
Industrial ProtocolsEtherNet/IP, Modbus TCP, PROFINET
ManagementBack Pressure Flow Control, BOOTP, DDM, DHCP Option 66/67/82, DHCP Server/Client, Fiber check, Flow control, IPv4/IPv6, LLDP, Port Mirror, RARP, RMON, SMTP, SNMP Inform, SNMPv1/v2c/v3, Syslog, Telnet, TFTP
MIBBridge MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, Q-BRIDGE MIB, RMON MIB Groups 1, 2, 3, 9, RSTP MIB
Redundancy ProtocolsLink Aggregation, MSTP, RSTP, STP, Turbo Chain, Turbo Ring v1/v2
SecurityBroadcast storm protection, HTTPS/SSL, MAC ACL, TACACS+, MAB authentication, Sticky MAC, NTP authentication, Port Lock, RADIUS, SSH
Time ManagementIEEE 1588v2 PTP (software-based), NTP Server/Client, SNTP

IGMP Groups256
Jumbo Frame Size9.6 KB
MAC Table Size8 K
Max. No. of VLANs64
Packet Buffer Size12 Mbits
Priority Queues4
VLAN ID RangeVID 1 to 4094

Storage PortUSB Type A

LED IndicatorsPWR1, PWR2, STATE, FAULT, 10/100M (TP port), 10/100/1000M (Gigabit Combo port), MSTR/HEAD, CPLR/TAIL, PoE

Console PortUSB-serial console (Type B connector)

Alarm Contact Channels1, Relay output with current carrying capacity of 0.5 A @ 48 VDC
Digital Input Channels1
Digital InputsMax. input current: 8 mA
+13 to +30 V for state 1
-30 to +3 V for state 0
ButtonsReset button

Ethernet InterfaceTurbo Ring, Master, Coupler, Reserve

Connection2 removable 4-contact terminal block(s)
Input Voltage12/24/48 VDC, Redundant dual inputs
Input Current4.08 A @ 48 VDC
Operating Voltage12 to 57 VDC (> 50 VDC for PoE+ output recommended)
Overload Current ProtectionSupported
Reverse Polarity ProtectionSupported
Operating Voltage12 to 57 VDC (> 50 VDC for PoE+ output recommended)
Max. PoE Power Output per Port60 W
Power Consumption (Max.)Max. 18.96 W full loading without PDs’ consumption

HousingMetal
IP RatingIP40
Dimensions49.1 x 135 x 116 mm (1.93 x 5.31 x 4.57 in)
Weight910 g (2.00 lb)
InstallationDIN-rail mounting, Wall mounting (with optional kit)

Operating TemperatureEDS-P506E-4PoE-2GTXSFP: -10 to 60°C (14 to 140°F)
EDS-P506E-4PoE-2GTXSFP-T: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included)-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)

EMCEN 61000-6-2/-6-4
EMICISPR 32, FCC Part 15B Class A
EMSIEC 61000-4-6 CS: 10 V
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-11 DIPs
IEC 61000-4-8 PFMF
Power SubstationIEEE 1613, IEC 61850-3 Edition 2.0
RailwayEN 50121-4
Traffic ControlNEMA TS2
VibrationIEC 60068-2-6
SafetyUL 61010-2-201, EN 61010-2-201
ShockIEC 60068-2-27
BumpIEC 61850-3 Edition 2.0
FreefallIEC 60068-2-31

Time755,167 hrs
StandardsTelcordia (Bellcore), GB

Warranty Period5 years
DetailsSee www.moxa.com/warranty

Models