PTC-101 Series

Introduction
The PTC-101 Ethernet-to-fiber media converters convert from 10/100BaseT(X) to 100BaseFX. Models are available with either SC, ST, or LC connectors. The PTC-101 converters eliminate the need for additional wiring, and support IEEE 802.3 and IEEE 802.3u/x protocols with 10/100M, full/half-duplex, and MDI/MDI-X auto-sensing to provide a total solution for your industrial Ethernet networks. The PTC-101 is compliant with mandatory sections of IEC 61850-3, covering operating temperature, power input voltage, surge, ESD, and vibration, as well as conformal coating and power insulation, making the media converters suitable for a variety of industrial applications.

PTC-101 Series

Features and Benefits

  • 10/100BaseT(X) auto-negotiation and auto-MDI/MDI-X
  • Link Fault Pass-Through (LFPT)
  • Power failure alarm by relay output (LV model only)
  • -40 to 85°C operating temperature range
  • Redundant dual DC power inputs (LV model only)
  • Integrated high-reliability power supply eliminates the need for external power transformer

Certifications

Download Datasheet

Description

Introduction
The PTC-101 Ethernet-to-fiber media converters convert from 10/100BaseT(X) to 100BaseFX. Models are available with either SC, ST, or LC connectors. The PTC-101 converters eliminate the need for additional wiring, and support IEEE 802.3 and IEEE 802.3u/x protocols with 10/100M, full/half-duplex, and MDI/MDI-X auto-sensing to provide a total solution for your industrial Ethernet networks. The PTC-101 is compliant with mandatory sections of IEC 61850-3, covering operating temperature, power input voltage, surge, ESD, and vibration, as well as conformal coating and power insulation, making the media converters suitable for a variety of industrial applications.

Specification

Input Current LV-DC models: 150 mA @ 20 to 72 VDC
HV-AC models: 200 to 350 mA @ 100 to 240 VAC
HV-DC models: 47 mA @ 88 VDC
Input Voltage LV-DC models: 20 to 72 VDC
HV-AC models: 100 to 240 VAC
HV-DC models: 88 to 300 VDC
Overload Current Protection Supported
Power Consumption LV-DC models: 150 mA @ 20 to 72 VDC
HV-AC models: 200 to 350 mA @ 100 to 240 VAC
HV-DC models: 47 mA @ 88 VDC

Housing Metal
Dimensions 152.15 x 126.46 x 66.65 mm (5.99 x 4.86 x 2.62 in)
Weight Packaged: 875 g (1.92 lb)
Product only: 690 g (1.52 lb)
Installation DIN-rail mounting

Operating Temperature -40 to 85°C (-40 to 185°F)
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)

EMC EN 55032/24
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF
IEC 61000-4-11
Safety EN 60950-1, UL 60950-1
Environmental Testing IEC 60068-2-1
IEC 60068-2-14
IEC 60068-2-2
IEC 60068-2-3
Vibration IEC 60068-2-6
Hazardous Locations Standard models: UL/cUL Class I Division 2 Groups A/B/C/D
-IEX models: UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2, IECEx
Power Substation IEC 61850-3

Time 1,211,613 hrs
Standards MIL-HDBK-217F

Warranty Period 5 years
Details See www.moxa.com/warranty

Models