PT-7728 Series

Introduction
The PT-7728 is designed to meet the demands of power substation automation systems (IEC 61850-3, IEEE 1613), and railway applications (EN 50121-4), and also features critical packet prioritization (GOOSE and SMVs) and a built-in MMS server. The PT-7728’s Gigabit and Fast Ethernet backbone, redundant ring, and 24 VDC, 48 VDC, or 110/220 VDC/VAC dual isolated redundant power supplies increase the reliability of your communications and save on cabling/wiring costs. The modular design of the PT-7728 also makes network planning easy, and allows greater flexibility by letting you install up to 4 Gigabit ports and 24 Fast Ethernet ports. Along with the optional front or rear wiring, these features together make the PT-7728 suitable for a variety of industrial applications.

 

Additional Features and Benefits

  • Switch data modeling based on the IEC 61850-90-4 standard
  • IEEE 1588v2 PTP (Precision Time Protocol) for time synchronization of networks (PTP models only)
  • VLAN Unaware: Supports priority-tagged frames to be received by specific IEDs
  • DHCP Option 82 for IP address assignment with different policies
  • EtherNet/IP and Modbus TCP industrial Ethernet protocols supported
  • Line-swap fast recovery
  • Configurable by web browser, Telnet/serial console, CLI, Windows utility, and ABC-01 automatic backup configurator
  • IGMP snooping and GMRP for filtering multicast traffic from industrial Ethernet protocols
  • Supports advanced VLAN capability with Q-in-Q tagging
  • IEEE 802.3ad, LACP for optimum bandwidth utilization
  • Bandwidth management to prevent unpredictable network status
  • Multi-port mirroring for online debugging
  • Automatic warning by exception through email and relay output
  • RMON for proactive and efficient network monitoring
  • Automatic recovery of connected device’s IP addresses

 

Cybersecurity Features

  • User passwords with multiple levels of security protect against unauthorized configuration
  • SSH/HTTPS is used to encrypt passwords and data
  • Lock switch ports with 802.1X port-based network access control so that only authorized clients can access the port
  • RADIUS/TACACS+ allows you to manage passwords from a central location
  • 802.1Q VLAN allows you to logically partition traffic transmitted between selected switch ports
  • Secure switch ports so that only specific devices and/or MAC addresses can access the ports
  • Disable one or more ports to block network traffic
  • SNMPv3 provides encrypted authentication and access security

PT-7728 Series

Features and Benefits

  • IEC 61850-3, IEEE 1613 (power substations), and EN 50121-4 (railway applications) compliant
  • IEC 62439-3 Clause 4 (PRP) and Clause 5 (HSR) compliant 
  • Built-in MMS server based on IEC 61850-90-4 switch data modeling for power SCADA
  • Complies with a portion of EN 50155 specifications
  • Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches),  RSTP/STP, and MSTP for network redundancy
  • VLAN Unaware: Supports priority-tagged frames to be received by specific IEDs
  • Up to 12 ports with M12 connectors
  • Isolated redundant power inputs with universal 24 VDC, 48 VDC, or 110/220 VDC/VAC power supply range
  • -40 to 85°C operating temperature range

Certifications

Download Datasheet

Description

Introduction
The PT-7728 is designed to meet the demands of power substation automation systems (IEC 61850-3, IEEE 1613), and railway applications (EN 50121-4), and also features critical packet prioritization (GOOSE and SMVs) and a built-in MMS server. The PT-7728’s Gigabit and Fast Ethernet backbone, redundant ring, and 24 VDC, 48 VDC, or 110/220 VDC/VAC dual isolated redundant power supplies increase the reliability of your communications and save on cabling/wiring costs. The modular design of the PT-7728 also makes network planning easy, and allows greater flexibility by letting you install up to 4 Gigabit ports and 24 Fast Ethernet ports. Along with the optional front or rear wiring, these features together make the PT-7728 suitable for a variety of industrial applications.

 

Additional Features and Benefits

  • Switch data modeling based on the IEC 61850-90-4 standard
  • IEEE 1588v2 PTP (Precision Time Protocol) for time synchronization of networks (PTP models only)
  • VLAN Unaware: Supports priority-tagged frames to be received by specific IEDs
  • DHCP Option 82 for IP address assignment with different policies
  • EtherNet/IP and Modbus TCP industrial Ethernet protocols supported
  • Line-swap fast recovery
  • Configurable by web browser, Telnet/serial console, CLI, Windows utility, and ABC-01 automatic backup configurator
  • IGMP snooping and GMRP for filtering multicast traffic from industrial Ethernet protocols
  • Supports advanced VLAN capability with Q-in-Q tagging
  • IEEE 802.3ad, LACP for optimum bandwidth utilization
  • Bandwidth management to prevent unpredictable network status
  • Multi-port mirroring for online debugging
  • Automatic warning by exception through email and relay output
  • RMON for proactive and efficient network monitoring
  • Automatic recovery of connected device’s IP addresses

 

Cybersecurity Features

  • User passwords with multiple levels of security protect against unauthorized configuration
  • SSH/HTTPS is used to encrypt passwords and data
  • Lock switch ports with 802.1X port-based network access control so that only authorized clients can access the port
  • RADIUS/TACACS+ allows you to manage passwords from a central location
  • 802.1Q VLAN allows you to logically partition traffic transmitted between selected switch ports
  • Secure switch ports so that only specific devices and/or MAC addresses can access the ports
  • Disable one or more ports to block network traffic
  • SNMPv3 provides encrypted authentication and access security

Specification

Filter 802.1Q, GMRP, GVRP, IGMP v1/v2c, QinQ VLAN, VLAN unaware
Industrial Protocols EtherNet/IP, Modbus TCP
Power Substation IEC 61850 QoS, MMS
Management Back Pressure Flow Control, BOOTP, DHCP Option 66/67/82, DHCP Server/Client, Flow control, HTTP, IPv4/IPv6, LLDP, Port Mirror, RARP, RMON, SMTP, SNMP Inform, SNMPv1/v2c/v3, Syslog, Telnet, TFTP, Fiber check
MIB Bridge MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, Q-BRIDGE MIB, RMON MIB Groups 1, 2, 3, 9, RSTP MIB
Redundancy Protocols All models: Link Aggregation, MSTP, RSTP, STP, Turbo Chain, Turbo Ring v1/v2
PTP models: HSR, PRP
Security Broadcast storm protection, HTTPS/SSL, TACACS+, Port Lock, RADIUS, Rate Limit, SSH
Time Management All models (except PTP models): NTP Server/Client, SNTP
PTP models: NTP Server/Client, SNTP, IEEE 1588 PTP v1/v2 (hardware-based)

IGMP Groups 256
Max. No. of VLANs 64
Priority Queues 4
VLAN ID Range VID 1 to 4094

Console Port RS-232 (RJ45)

Alarm Contact Channels Resistive load: 3 A @ 30 VDC, 240 VAC

Connection 10-pin terminal block
Input Current PT-7728-24 Series: 2.38 A @ 24 VDC
PT-7728-48 Series: 1.12 A @ 48 VDC
PT-7728-HV Series: 0.49/0.26 A @ 110/220 VAC, 0.59/0.30 A @ 110/220 VDC
Input Voltage -24-24/-48-48/-HV-HV/-24-HV/-48-HV models: Redundant power modules
PT-7728-24 Series: 24 VDC (18 to 36 VDC)
PT-7728-48 Series: 48 VDC (36 to 72 VDC)
PT-7728-HV Series: 110/220 VAC/VDC (85 to 264 VAC, 88 to 300 VDC)
Overload Current Protection Supported
Reverse Polarity Protection Supported

Housing Aluminum
IP Rating IP30
Dimensions (without ears) 440 x 44 x 325 mm (17.32 x 1.73 x 12.80 in)
Weight 5900 g (13.11 lb)
Installation 19-inch rack mounting

Operating Temperature -40 to 85°C (-40 to 185°F)
Note: Cold start requires minimum of 100 VAC @ -40°C
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)

EMI EN 55032 Class A, CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 35 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
Power Substation IEC 61850-3, IEEE 1613
Safety EN 60950-1, UL 60950-1, CSA C22.2 No. 60950-1
Railway EN 50121-4, EN 50155 (complies with a portion of EN 50155 specifications)
Traffic Control NEMA TS2

Time 393,828 hrs
Standards Telcordia SR332

Warranty Period 5 years
Details See www.moxa.com/warranty

Models