NPort S8000 Series

Introduction
The NPort S8000 Series combines an industrial device server with a full-function managed Ethernet switch with 4 RS-232/422/485 serial ports, allowing you to easily install, manage, and maintain the product. Combining a device server and switch in one product allows you to save space in your cabinet, reduce overall power consumption, and reduce costs, since you will not need to purchase a switch and serial device server separately.

 

Supports the Full Range of NPort 5000 Series Device Server Functions
The NPort S8000 Series supports the complete array of NPort 5000 device server functions. You can network your existing serial devices by connecting up to 4 serial devices through Ethernet ports, with only basic configuration required. In addition, data transmission between the serial and Ethernet interfaces is bidirectional.

 

Full-function Managed Ethernet Switch
The NPort S8000 Series has a built-in full-function managed Ethernet switch that supports QoS, IGMP-snooping/GMRP, VLAN, Port Trunking, SNMPv1/v2c/v3, and IEEE 802.1X, allowing you to handle virtually any kind of application. Ethernet redundancy, which is used to increase the reliability and availability of your industrial Ethernet network, is provided by Moxa’s Turbo Ring and Turbo Chain technology (recovery time < 20 ms) or RSTP/STP (IEEE 802.1w/D).

Ring Redundancy at the Device Level
Device-level communication networks for industrial automation are very critical since they are used to control and monitor device processes. The reliability of these communications depends on ring redundancy at the device level, which is designed to provide fast network fault detection and reconfiguration in order to support the most demanding control applications. The NPort S8000 Series integrates a full function NPort device server with an industrial switch to carry serial and Ethernet devices at the same time.

In addition, the NPort S8000 Series can also achieve ring redundancy with standard STP/RSTP and Moxa’s proprietary Turbo Ring or Turbo Chain 2 redundancy protocols. This all-in-one design can be used to optimize and simplify your device network and enhance reliability.

Appreance

NPort S8000 Series

Features and Benefits

  • 4-port RS-232/422/485 serial device server
  • Serial QoS for configuring serial data transmission priority
  • Built-in managed Ethernet switch
  • S8455I fiber models: 2 fiber Ethernet ports and 3 Ethernet ports
  • S8455I all-copper models: 5 Ethernet ports
  • microSD card for configuration backup/duplication and event logs, and data buffering when cloud connection is lost
  • Ethernet redundancy with Turbo Ring and Turbo Chain (recovery time < 20 ms) or RSTP/STP (IEEE 802.1w/D) supported
  • QoS, IGMP-snooping/GMRP, VLAN, LACP, SNMPv1/v2c/v3, RMON supported
  • Cascading Ethernet ports for easy wiring
  • Secure data access with WEP, WPA, WPA2
  • 2 kV isolation for serial signals (isolation models)
  • Adjustable pull high/low resistor for RS-485 ports
  • Surge protection for serial, Ethernet, and power

Certifications

Download Datasheet

Description

Introduction
The NPort S8000 Series combines an industrial device server with a full-function managed Ethernet switch with 4 RS-232/422/485 serial ports, allowing you to easily install, manage, and maintain the product. Combining a device server and switch in one product allows you to save space in your cabinet, reduce overall power consumption, and reduce costs, since you will not need to purchase a switch and serial device server separately.

 

Supports the Full Range of NPort 5000 Series Device Server Functions
The NPort S8000 Series supports the complete array of NPort 5000 device server functions. You can network your existing serial devices by connecting up to 4 serial devices through Ethernet ports, with only basic configuration required. In addition, data transmission between the serial and Ethernet interfaces is bidirectional.

 

Full-function Managed Ethernet Switch
The NPort S8000 Series has a built-in full-function managed Ethernet switch that supports QoS, IGMP-snooping/GMRP, VLAN, Port Trunking, SNMPv1/v2c/v3, and IEEE 802.1X, allowing you to handle virtually any kind of application. Ethernet redundancy, which is used to increase the reliability and availability of your industrial Ethernet network, is provided by Moxa’s Turbo Ring and Turbo Chain technology (recovery time < 20 ms) or RSTP/STP (IEEE 802.1w/D).

Ring Redundancy at the Device Level
Device-level communication networks for industrial automation are very critical since they are used to control and monitor device processes. The reliability of these communications depends on ring redundancy at the device level, which is designed to provide fast network fault detection and reconfiguration in order to support the most demanding control applications. The NPort S8000 Series integrates a full function NPort device server with an industrial switch to carry serial and Ethernet devices at the same time.

In addition, the NPort S8000 Series can also achieve ring redundancy with standard STP/RSTP and Moxa’s proprietary Turbo Ring or Turbo Chain 2 redundancy protocols. This all-in-one design can be used to optimize and simplify your device network and enhance reliability.

Appreance

Specification

10/100BaseT(X) Ports (RJ45 connector) NPort S8455I/S8455I-T: 5
NPort S8455I-MM-SC/SS-SC Models: 3
100BaseFX Ports (multi-mode SC connector) NPort S8455I-MM-SC Models: 2
100BaseFX Ports (single-mode SC connector) NPort S8455I-SS-SC Models: 2
Optical Fiber
Optical Fiber Read more
Magnetic Isolation Protection 1.5 kV (built-in)
Standards IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1X for authentication
IEEE 802.3 for 10BaseT
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for flow control

IGMP Groups 256
Max. No. of VLANs 64
Priority Queues 4
VLAN ID Range VID 1 to 4094

Configuration Options Web Console (HTTP/HTTPS), Windows Utility, Serial Console, Telnet Console
Management BOOTP, Device Search Utility (DSU), DHCP Client, DHCP Option 82, HTTP, IPv4, LLDP, Port Mirror, RMON, SMTP, SNMPv1/v2c/v3, Syslog, TCP/IP, Telnet, Web Console
Filter 802.1Q, GVRP, IGMP v1/v2
Windows Real COM Drivers Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2/2016/2019 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded
Linux Real TTY Drivers Kernel versions: 2.4.x, 2.6.x, 3.x, 4.x, and 5.x
Fixed TTY Drivers SCO UNIX, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X, macOS 10.12, macOS 10.13, macOS 10.14, macOS 10.15
Android API Android 3.1.x and later
Time Management SNTP
MIB Bridge MIB, Device Settings MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, Q-BRIDGE MIB, RFC1213, RFC1317, RMON MIB Groups 1, 2, 3, 9, RSTP MIB
Redundancy Protocols RSTP, Turbo Chain, Turbo Ring v1, Turbo Ring v2
Security HTTPS, SSL, SSH
Authentication Local Account Accessibility, RADIUS

Connector DB9 male
No. of Ports 4
Operation Modes Disabled, Real COM mode, RFC2217 mode, TCP Client mode, TCP Server mode, UDP mode
Baudrate 50 bps to 921.6 kbps
Data Bits 5, 6, 7, 8
Stop Bits 1, 1.5, 2
Parity None, Even, Odd, Space, Mark
Flow Control None, RTS/CTS, XON/XOFF
Isolation 2 kV
RS-485 Data Direction Control ADDC® (automatic data direction control)
Pull High/Low Resistor for RS-485 1 kilo-ohm, 150 kilo-ohms
Terminator for RS-485 120 ohms
Console Port RS-232 (TxD, RxD, GND), 8-pin RJ45 (19200, n, 8, 1)
Serial Standards RS-232/422/485

RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND

Ethernet Interface Coupler, Master, Reserved, Turbo Ring

No. of Power Inputs 2
Power Connector 2 removable 6-contact terminal block(s)
Input Current 935 mA @ 12 VDC
Input Voltage 12 to 48 VDC

Housing Metal
Dimensions 73.1 x 134 x 125 mm (2.88 x 5.27 x 4.92 in)
Weight 578 g (1.27 lb)
Installation DIN-rail mounting, Wall mounting (with optional kit)

Operating Temperature Standard Temp. Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 75°C (-40 to 167°F)
Ambient Relative Humidity 5 to 95% (non-condensing)

EMC EN 55032/24
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Signal: 1 kV
IEC 61000-4-5 Surge: Power: 1 kV; Signal: 0.25 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF
Environmental Testing IEC 60068-2-1
IEC 60068-2-3
Hazardous Locations Class I Division 2
Safety EN 60950-1, IEC 60950-1, UL 508, UL 60950-1
Shock IEC 60068-2-27
Vibration IEC 60068-2-6

Time NPort S8455I/S8455I-T: 287,354 hrs
NPort S8455I-MM-SC/MM-SC-T: 200,951 hrs
NPort S8455I-SS-SC/SS-SC-T: 286,993 hrs
Standards Telcordia (Bellcore) Standard TR/SR

Warranty Period 5 years
Details See www.moxa.com/warranty

Models