ioPAC 8500 Series (85M) Modules

Introduction
Moxa’s ioPAC 8500 Series 85M Modules can be installed in both ioPAC 8500 and ioPAC 8600 Series devices. Modules are available with DI/Os, AIs, Fast AIs, and serial interfaces, giving users a wide variety of options to choose from and allowing them to select the I/O combination that best fits their target application. All 85M modules are designed for railway industry applications, and as such, are compliant with EN 50121-3-2, EN 50121-4, and a portion of the EN 50155 specifications. In addition, these modules all support a wide operating temperature range of -40 to 75°C for reliable operation even in harsh environments.

ioPAC 8500 Series (85M) Modules

Features and Benefits

  • Compliant with EN 50121-3-2, EN 50121-4, and a portion of EN 50155 specifications
  • Rugged and compact design for harsh environments
  • Expand the I/O and communication capabilities of your ioPAC 8600 or 8500 Series device
  • Wide operating temperature range: -40 to 75°C (-40 to 167°F)
  • Millisecond timestamp granularity for digital input and analog input
  • Supports sampling rates up to 40 kHz for analog input
  • Pre-recording for analog input data logging
  • Up to 4 3-in-1 RS-232/422/485 serial ports

Certifications

Download Datasheet

View List

Description

Introduction
Moxa’s ioPAC 8500 Series 85M Modules can be installed in both ioPAC 8500 and ioPAC 8600 Series devices. Modules are available with DI/Os, AIs, Fast AIs, and serial interfaces, giving users a wide variety of options to choose from and allowing them to select the I/O combination that best fits their target application. All 85M modules are designed for railway industry applications, and as such, are compliant with EN 50121-3-2, EN 50121-4, and a portion of the EN 50155 specifications. In addition, these modules all support a wide operating temperature range of -40 to 75°C for reliable operation even in harsh environments.

Specification

Voltage24 VDC
ConnectorSpring-type Euroblock terminal
Counter Frequency5 kHz
Dry ContactOn: short to GND
Off: open
I/O ModeDI, event counter, or frequency
Points per COM8 channels
Sensor TypeDry contact
Wet Contact (NPN or PNP)
Wet Contact (DI to GND)On: 10 to 30 VDC
Off: 0 to 3 VDC

Voltage24 VDC
ConnectorSpring-type Euroblock terminal
Current Rating200 mA per channel
I/O TypeSink
I/O ModeDO or PWM
Over-Current Protection0.65 A per channel @ 25°C
Over-Temperature Shutdown175°C (typical), 150°C (min.)
Over-Voltage Protection85M-2600-T: 45 VDC (typical)
45 VDC (typical)
Pulse Output Frequency5 kHz

Accuracy±0.1% FSR @ 25°C
±0.3% FSR @ -40 to 75°C
Built-in Resistor for Current Input85M-3800-T/3801-T: 125 ohms
ConnectorSpring-type Euroblock terminal
Historical Data Buffering85M-3801-T/3811-T: 60 KB per channel, 6-second data buffer at 5 kHz
I/O TypeDifferential
Input Impedance85M-3800-T/3801-T: 125 ohms (min.)
85M-3810-T: 200 kilo-ohms (min.)
85M-3811-T: 20 mega-ohms (min.)
Input Range85M-3800-T/3801-T: 4 to 20 mA (with burn-out detection)
85M-3810-T/3811-T: 0 to 10 VDC
Resolution16 bits
Sampling Rate85M-3800-T/3810-T:
All channels: 100 samples/sec
Per channel: 12.5 samples/sec
85M-3801-T/3811-T:All channels: 40k samples/sec
Per channel: 5k samples/sec

Accuracy±0.1% FSR @ 25°C
±0.3% FSR @ -40 to 75°C
ConnectorSpring-type Euroblock terminal
Input Connection2- or 3-wire
Input Impedance625 kilo-ohms (min.)
Sensor TypeJPT100, JPT200, JPT500 (-200 to 640°C)
JPT1000 (-200 to 350°C)
NI100, NI50, NI500 (-60 to 250°C)
NI1000 (-60 to 150°C)
NI120 (-80 to 260°C)
PT1000 (-200 to 350°C)
PT50, PT100, PT200, PT500 (-200 to 850°C)
Resistance of 310, 620, 1250, and 2200 ohms
Resolution0.1°C or 0.1 ohms
Sampling RateAll channels: 12 samples/sec
Per channel: 2 samples/sec

Millivolt Accuracy±0.1% FSR @ 25°C
±0.3% FSR @ -40 to 75°C
ConnectorSpring-type Euroblock terminal
Input Impedance1 mega-ohms (min.)
Millivolt Type±19.532 mV
±39.062 mV
±78.126 mV
Fault and over-voltage protection: -35 to +35 VDC (power off); -25 to +30 VDC (power on)
Resolution16 bits
Sampling RateAll channels: 12 samples/sec
Per channel: 1.5 samples/sec
Sensor TypeJ, K, T, E, R, S, B, N

Baudrate300 bps to 921.6 kbps
ParityNone, Even, Odd
Serial StandardsRS-232/422/485
Data Bits7, 8
Stop Bits1, 2

RS-232TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422Tx+, Tx-, Rx+, Rx-, GND
RS-485-2wData+, Data-, GND
RS-485-4wTx+, Tx-, Rx+, Rx-, GND

Power Consumption85M-1602-T: 50.0 mA @ 24 VDC
85M-2600-T: 35.4 mA @ 24 VDC
85M-3800-T: 43.8 mA @ 24 VDC
85M-3801-T: 43.8 mA @ 24 VDC
85M-3810-T: 43.3 mA @ 24 VDC
85M-3811-T: 521 mA @ 24 VDC
85M-5401-T: 51.7 mA @ 24 VDC
85M-6600-T: 27.7 mA @ 24 VDC
85M-6810-T: 24.1 mA @ 24 VDC

Dimensions25 x 128.2 x 85.5 mm (0.98 x 5.05 x 3.37 in)
WeightUnder 80 g
WiringI/O cable, 14 to 28 AWG

Operating Temperature-40 to 75°C (-40 to 167°F)
Storage Temperature (package included)-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
Altitude2000 m
Note: Please contact Moxa if you require products guaranteed to function properly at higher altitudes.

SafetyUL 508
EMCEN 55032/24
EN 61000-6-2/-6-4
EMICISPR 32, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 5100 MHz to 6000 MHz: 3 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
ShockIEC 60068-2-27
VibrationIEC 60068-2-6
RailwayEN 50121-4
EN 50155 (complies with a portion of EN 50155 specifications)

Time85M-1602-T: 1,132,561 hrs
85M-2600-T: 792,571 hrs
85M-3800-T: 1,512,906 hrs
85M-3801-T: 1,426,112 hrs
85M-3810-T: 1,530,690 hrs
85M-3811-T: 1,426,112 hrs
85M-5401-T: 596,611 hrs
85M-6600-T: 571,446 hrs
85M-6810-T: 2,324,891 hrs
StandardsTelcordia SR332

Warranty Period5 years
DetailsSee www.moxa.com/warranty

Models