EDS-4012 Series

Introduction
The EDS-4012 Series is a range of 12-port managed Fast Ethernet switches with the option for four 1 Gbps fiber-optic uplink ports. This Series also offers models with four 10/100BaseT(X) 802.3af (PoE), 802.3at (PoE+), and 802.3bt-compliant Ethernet PoE port options to connect high-bandwidth PoE devices.

 

Redundant Ethernet technologies such as Turbo Ring, Turbo Chain, and RSTP/STP increase the reliability of your system and improve the availability of your network backbone. The EDS-4012 Series is designed specifically for demanding applications such as video and process monitoring, ITS, and DCS systems, all of which can benefit from a scalable backbone.

 

The EDS-4012 Series is compliant with the IEC 62443-4-2 and IEC 62443-4-1 Industrial Cybersecurity certifications, which cover both product security and secure development life-cycle requirements, helping our customers meet the compliance requirements of secure industrial network design.

EDS-4012 Series

Features and Benefits

  • Developed according to the IEC 62443-4-1 and compliant with the IEC 62443-4-2 industrial cybersecurity standards
  • Support for IEEE 802.3bt PoE for up to 90 W output per port
  • Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches)  , and RSTP/STP for network redundancy
  • Wide range of power input options for flexible deployment
  • Compact and flexible housing design to fit into confined spaces
  • Supports MXstudio for easy, visualized industrial network management

Certifications

Download Datasheet

Description

Introduction
The EDS-4012 Series is a range of 12-port managed Fast Ethernet switches with the option for four 1 Gbps fiber-optic uplink ports. This Series also offers models with four 10/100BaseT(X) 802.3af (PoE), 802.3at (PoE+), and 802.3bt-compliant Ethernet PoE port options to connect high-bandwidth PoE devices.

 

Redundant Ethernet technologies such as Turbo Ring, Turbo Chain, and RSTP/STP increase the reliability of your system and improve the availability of your network backbone. The EDS-4012 Series is designed specifically for demanding applications such as video and process monitoring, ITS, and DCS systems, all of which can benefit from a scalable backbone.

 

The EDS-4012 Series is compliant with the IEC 62443-4-2 and IEC 62443-4-1 Industrial Cybersecurity certifications, which cover both product security and secure development life-cycle requirements, helping our customers meet the compliance requirements of secure industrial network design.

Specification

Filter GMRP, GVRP, GARP, 802.1Q VLAN, IGMP Snooping v1/v2/v3, IGMP Querier
Management IPv4/IPv6, Flow control, Back Pressure Flow Control, DHCP Server/Client, ARP, RARP, LLDP, Port Mirror, Linkup Delay, SMTP, SNMP Trap, SNMP Inform, SNMPv1/v2c/v3, RMON, TFTP, SFTP, HTTP, HTTPS, Telnet, Syslog, Private MIB
MIB P-BRIDGE MIB, Q-BRIDGE MIB, IEEE8021-SPANNING-TREE-MIB, IEEE8021-PAE-MIB, IEEE8023-LAG-MIB, LLDP-EXT-DOT1-MIB, LLDP-EXT-DOT3-MIB, SNMPv2-MIB, RMON MIB Groups 1, 2, 3, 9
Redundancy Protocols STP, RSTP, Turbo Ring v2, Turbo Chain, Ring Coupling, Dual-Homing, Link Aggregation
Security Broadcast storm protection, Rate Limit, Trust access control, Static Port Lock, MAC Sticky, HTTPS/SSL, SSH, RADIUS, TACACS+, Login and Password Policy
Time Management  SNTP, NTP Server/Client, NTP Authentication
Protocols IPv4/IPv6, TCP/IP, UDP, ICMP, ARP, RARP, TFTP, DNS, NTP Client, DHCP Server, DHCP Client, 802.1X, QoS, HTTPS, HTTP, Telnet, SMTP, SNMPv1/v2c/v3, RMON, Syslog

MAC Table Size 16 K
Jumbo Frame Size 9.216 KB
Max. No. of VLANs 256
VLAN ID Range VID 1 to 4094
IGMP Groups 512
Priority Queues 4
Packet Buffer Size 1 MB

LED Indicators PWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNC

Console Port  RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)

USB Connector USB Type A (Reserved)

Alarm Contact Channels 1, Relay output with current carrying capacity of 1 A @ 24 VDC
Digital Input Channels 1
Digital Inputs +13 to +30 V for state 1
-30 to +3 V for state 0
Max. input current: 8 mA
Buttons Reset button

DIP Switches Turbo Ring, Master, Coupler, Reserve

Connection 2 removable 4-contact terminal block(s)
Pre-installed Power Module -LV/-LV-T models: PWR-100–LV
-HV/-HV-T models: PWR-105-HV-I
-LVA/-LVA-T models: PWR-101-LV-BP-I
-LVB/-LVB-T models: PWR-103-LV-VB-I
Note The EDS-4012 Series supports modular power supplies. The model names and power parameters are determined by the installed power module.

For example:
EDS-4012-4GS-T + PWR-100–LV = EDS-4012-4GS-LV-T
EDS-4012-4GS-T + PWR-105-HV-I = EDS-4012-4GS-HV-T

If you install a different power module, refer to the specifications of the corresponding model. For example, if you replace the power module of the EDS-4012-4GS–LV-T
with the PWR-105–HV-I, refer to the specifications of the EDS-4012–4GS-HV-T.

Input Voltage -LV/-LV-T models: 12/24/48 VDC, Redundant dual inputs
-HV/-HV-T models: 110/220 VDC/VAC, Single input
-LVA/-LVA-T models: 48 VDC, Redundant dual inputs
-LVB/-LVB-T models: 12/24/48 VDC, Redundant dual inputs
Operating Voltage -LV/-LV-T models: 9.6 to 60 VDC
-HV/-HV-T models: 88 to 300 VDC, 85 to 264 VAC
-LVA/-LVA-T models: 44 to 57 VDC (>52 VDC for PoE+ output recommended)
-LVB/-LVB-T models: 12 to 57 VDC (>52 VDC for PoE+ output recommended)
Input Current -LV/-LV-T models: 12-48 VDC, 1.50-0.40 A or 24 VDC, 0.70 A
-HV/-HV-T models: 110-220 VAC, 50-60 Hz, 0.30-0.20 A or 110-220 VDC, 0.30-0.20 A
-LVA/-LVA-T models: 48 VDC, 5.42 A
-LVB/-LVB-T models: 12/48 VDC, 7.46/4.27 A or 24 VDC, 7.26 A
Power Consumption (Max.) EDS-4012-4GS-LV/-T models: 10.52 W
EDS-4012-4GS-HV-/T models: 12.22 W
EDS-4012-4GC-LV/-T models: 10.7 W
EDS-4012-4GC-HV/-T models: 13.35 WEDS-4012-8P-4GS-LVA/-T models:
Without PoE: 13.34 W
With PoE: Max. 240 W for total PD power consumption @ 48 VDC input

EDS-4012-8P-4GS-LVB/-T models:
Without PoE: 15.32 W
With PoE:
Max. 180 W for total PD power consumption @ 48 VDC input
Max. 150 W for total PD power consumption @ 24 VDC input (Max. 120 W for -T model)
Max. 62 W for total PD consumption @ 12 VDC input

Max. PoE Power Output per Port 90 W
Overload Current Protection Supported
Reverse Polarity Protection Supported

IP Rating IP40
Dimensions 55 x 140 x 120 mm (2.17 x 5.51 x 4.72 in)
Weight 827 g (1.82 lb)
Installation DIN-rail mounting, Wall mounting (with optional kit)
Housing Metal

Operating Temperature Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)

Industrial Cybersecurity IEC 62443-4-1
IEC 62443-4-2
Safety UL 61010-2-201, EN 62368-1 (LVD)
EMC EN 55032/35, EN 61000-6-2/-6-4
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
Maritime -LV/-LV-T, PoE/PoE-T models: DNV, ABS, NK, LR
Vibration IEC 60068-2-6
Shock IEC 60068-2-27
Freefall IEC 60068-2-32
Railway EN 50121-4
Traffic Control NEMA TS2
Power Substation IEC 61850-3, IEEE 1613 Class 1

Time EDS-4012-4GC-LV/-T models: 1,036,336 hrs
EDS-4012-4GC-HV/-T models: 497,392 hrs
EDS-4012-4GS-LV/-T models: 874,838 hrs
EDS-4012-4GS-HV/-T models: 456,870 hrs
EDS-4012-8P-4GS-LVA/-T models: 799,780 hrs
EDS-4012-8P-4GS-LVB/-T models: 759,924 hrs
Standards Telcordia SR332

Warranty Period 5 years
Details See www.moxa.com/warranty

Models