MGate 5111 Series

Introduction
MGate 5111 industrial Ethernet gateways convert data from Modbus RTU/ASCII/TCP, EtherNet/IP, or PROFINET to PROFIBUS protocols. All models are protected by a rugged metal housing, are DIN-rail mountable, and offer built-in serial isolation.

Modbus is one of the most widely used industrial communication protocols, and EtherNet/IP, PROFINET, and PROFIBUS are commonly used in factory automation and process automation. The MGate 5111 supports both Modbus RTU/ASCII/TCP master and slave modes, so that you can easily connect your Modbus device to PROFIBUS PLCs or DCSs, such as Siemens PLCs.

For system integration, the MGate 5111 can connect to EtherNet/IP PLC/SCADA systems, such as Rockwell Automation PLCs, to PROFIBUS PLC/DCS systems, or between a new Siemens PLC system that supports PROFINET to an existing PROFIBUS system. The MGate 5111 gateways are designed for easy configuration and quick maintenance. A handy web console can be used to implement remote maintenance tasks, and the configuration wizard UI lets you quickly set up your gateway. A comprehensive collection of troubleshooting tools reduce configuration time and system downtime. The rugged design is suitable for industrial applications, such as factory automation, power, oil and gas, water and wastewater, and other process automation industries.

Easy Configuration
The MGate 5111 Series has a user-friendly interface that lets you quickly set up protocol conversion routines for most applications, doing away with what were often time-consuming tasks in which users had to implement detailed parameter configurations one by one. With Quick Setup, you can easily access protocol conversion modes and finish the configuration in a few steps.

The MGate 5111 supports a web console and Telnet console for remote maintenance. Encryption communication functions, including HTTPS and SSH, are supported to provide better network security. In addition, system monitoring functions are provided to record network connections and system log events.

 

A Variety of Maintenance Functions
The MGate 5111 supports Protocol Diagnose and Traffic Monitor for easy troubleshooting, especially during the installation stage. Communication issues caused by incorrect software parameters, such as slave IDs and register addresses, or incorrect command configurations, can be fished out with Protocol Diagnose and Traffic Monitoring, which let you capture and check data to easily identify root causes.

MGate 5111 gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a Modbus device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators. When a PROFIBUS cable gets disconnected, the fault protection function executes actions on end devices identified by a predefined value set by the user.

MGate 5111 Series

Features and Benefits

  • Converts Modbus, PROFINET, or EtherNet/IP to PROFIBUS
  • Supports PROFIBUS DP V0 slave
  • Supports Modbus RTU/ASCII/TCP master/client and slave/server
  • Supports EtherNet/IP Adapter
  • Supports PROFINET IO device
  • Effortless configuration via web-based wizard
  • Built-in Ethernet cascading for easy wiring
  • Embedded traffic monitoring/diagnostic information for easy troubleshooting
  • Status monitoring and fault protection for easy maintenance
  • microSD card for configuration backup/duplication and event logs
  • Supports redundant dual DC power inputs and 1 relay output
  • Serial port with 2 kV isolation protection
  • -40 to 75°C wide operating temperature models available
  • Security features based on IEC 62443

Certifications

Download Datasheet

Description

Introduction
MGate 5111 industrial Ethernet gateways convert data from Modbus RTU/ASCII/TCP, EtherNet/IP, or PROFINET to PROFIBUS protocols. All models are protected by a rugged metal housing, are DIN-rail mountable, and offer built-in serial isolation.

Modbus is one of the most widely used industrial communication protocols, and EtherNet/IP, PROFINET, and PROFIBUS are commonly used in factory automation and process automation. The MGate 5111 supports both Modbus RTU/ASCII/TCP master and slave modes, so that you can easily connect your Modbus device to PROFIBUS PLCs or DCSs, such as Siemens PLCs.

For system integration, the MGate 5111 can connect to EtherNet/IP PLC/SCADA systems, such as Rockwell Automation PLCs, to PROFIBUS PLC/DCS systems, or between a new Siemens PLC system that supports PROFINET to an existing PROFIBUS system. The MGate 5111 gateways are designed for easy configuration and quick maintenance. A handy web console can be used to implement remote maintenance tasks, and the configuration wizard UI lets you quickly set up your gateway. A comprehensive collection of troubleshooting tools reduce configuration time and system downtime. The rugged design is suitable for industrial applications, such as factory automation, power, oil and gas, water and wastewater, and other process automation industries.

Easy Configuration
The MGate 5111 Series has a user-friendly interface that lets you quickly set up protocol conversion routines for most applications, doing away with what were often time-consuming tasks in which users had to implement detailed parameter configurations one by one. With Quick Setup, you can easily access protocol conversion modes and finish the configuration in a few steps.

The MGate 5111 supports a web console and Telnet console for remote maintenance. Encryption communication functions, including HTTPS and SSH, are supported to provide better network security. In addition, system monitoring functions are provided to record network connections and system log events.

 

A Variety of Maintenance Functions
The MGate 5111 supports Protocol Diagnose and Traffic Monitor for easy troubleshooting, especially during the installation stage. Communication issues caused by incorrect software parameters, such as slave IDs and register addresses, or incorrect command configurations, can be fished out with Protocol Diagnose and Traffic Monitoring, which let you capture and check data to easily identify root causes.

MGate 5111 gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a Modbus device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators. When a PROFIBUS cable gets disconnected, the fault protection function executes actions on end devices identified by a predefined value set by the user.

Specification

Industrial Protocols Modbus TCP Client (Master), Modbus TCP Server (Slave), PROFINET IO Device, EtherNet/IP Adapter
Configuration Options Web Console (HTTP/HTTPS), Device Search Utility (DSU), Telnet Console
Management ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, SSH, UDP, NTP Client
MIB RFC1213, RFC1317
Time Management NTP Client

Console Port RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
No. of Ports 1
Connector DB9 male
Serial Standards RS-232/422/485
Baudrate 50 bps to 921.6 kbps
Data Bits 7, 8
Parity None, Even, Odd, Space, Mark
Stop Bits 1, 2
Flow Control RTS Toggle (RS-232 only), RTS/CTS
Pull High/Low Resistor for RS-485 1 kilo-ohm, 150 kilo-ohms
Terminator for RS-485 120 ohms
Isolation 2 kV (built-in)

RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND

Configuration Options Serial Console
Industrial Protocols PROFIBUS DP-V0 Slave, Modbus RTU/ASCII Master, Modbus RTU/ASCII Slave

Mode Master, Slave
Functions Supported 1, 2, 3, 4, 5, 6, 15, 16, 23
Max. No. of Commands 128
Input Data Size 2048 bytes
Output Data Size 2048 bytes

Mode Client (Master), Server (Slave)
Functions Supported 1, 2, 3, 4, 5, 6, 15, 16, 23
Max. No. of Client Connections 16
Max. No. of Server Connections 32
Max. No. of Commands 128
Input Data Size 2048 bytes
Output Data Size 2048 bytes

Industrial Protocols PROFIBUS DP
No. of Ports 1
Connector DB9 female
Signals PROFIBUS D+, PROFIBUS D-, RTS, Signal Common, 5V
Baudrate 9600 bps to 12 Mbps
Isolation 2 kV (built-in)

Mode IO Device
Max. No. of IO Controller Connections 1 (for read/write)
Input Data Size 512 bytes
Output Data Size 512 bytes

Mode IO Device
Max. No. of IO Controller Connections 1 (for read/write)
Input Data Size 512 bytes
Output Data Size 512 bytes

Mode Adapter
CIP Objects Supported Identity, Message Router, Assembly, Connection Manager, TCP/IP interface, Ethernet link, Port
Max. No. of Scanner Connections 1 (for read-only), 1 (for read/write)
Input Data Size 496 bytes
Output Data Size 496 bytes

microSD Slot Up to 32 GB (SD 2.0 compatible)

Input Voltage 12 to 48 VDC
Input Current 416 mA @ 12 VDC
Power Connector Spring-type Euroblock terminal

Contact Current Rating Resistive load: 2 A @ 30 VDC

Housing Metal
IP Rating IP30
Dimensions 45.8 x 105 x 134 mm (1.8 x 4.13 x 5.28 in)
Weight 589 g (1.30 lb)

Operating Temperature MGate 5111: 0 to 60°C (32 to 140°F)
MGate 5111-T: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)

Safety EN 60950-1, UL 61010-2-201
EMC EN 61000-6-2/-6-4
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF
Hazardous Locations ATEX, Class I Division 2, IECEx
Freefall IEC 60068-2-32
Shock IEC 60068-2-27
Vibration IEC 60068-2-6, IEC 60068-2-64

Time 718,131 hrs
Standards Telcordia SR332

Warranty Period 5 years
Details See www.moxa.com/warranty

Models