TCC-120/120I Series

Introduction
The TCC-120 and TCC-120I are RS-422/485 converters/repeaters designed to extend RS-422/485 transmission distance. Both products have a superior industrial-grade design that includes DIN-rail mounting, terminal block wiring, and an external terminal block for power. In addition, the TCC-120I supports optical isolation for system protection. The TCC-120 and TCC-120I are ideal RS-422/485 converters/repeaters for critical industrial environments.

TCC-120/120I Series

Features and Benefits

  • Boosts serial signal to extend transmission distance
  • Wall mounting or DIN-rail mounting
  • Terminal block for easy wiring
  • Power input from terminal block
  • DIP switch setting for built-in terminator (120 ohm)
  • Boosts RS-422 or RS-485 signal, or converts RS-422 to RS-485
  • 2 kV isolation protection (TCC-120I)

Certifications

Download Datasheet

Description

Introduction
The TCC-120 and TCC-120I are RS-422/485 converters/repeaters designed to extend RS-422/485 transmission distance. Both products have a superior industrial-grade design that includes DIN-rail mounting, terminal block wiring, and an external terminal block for power. In addition, the TCC-120I supports optical isolation for system protection. The TCC-120 and TCC-120I are ideal RS-422/485 converters/repeaters for critical industrial environments.

Specification

RS-422 Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND

Input Current TCC-120: 65 mA @ 12 VDC
TCC-120I: 180 mA @ 12 VDC
Input Voltage 12 to 48 VDC
No. of Power Inputs 1
Overload Current Protection Supported
Power Connector Terminal block (for DC models)
Power Consumption TCC-120: 65 mA @ 12 VDC
TCC-120I: 180 mA @ 12 VDC

Housing Metal
IP Rating IP30
Dimensions 67 x 100.4 x 22 mm (2.64 x 3.93 x 0.87 in)
Weight 148 g (0.33 lb)
Installation DIN-rail mounting (with optional kit), Wall mounting

Operating Temperature Standard Models: -20 to 60°C (-4 to 140°F)
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)

EMC EN 55032/24
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
IEC 61000-4-5 Surge: Power: 1 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
Environmental Testing IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-3
Safety EN 60950-1, IEC 60950-1
Vibration IEC 60068-2-6

Time 1,949,025 hrs
Standards Telcordia (Bellcore), GB

Warranty Period 5 years
Details See www.moxa.com/warranty

Models